Search Results
AQUATHERM DESIGN & PLANNING GUIDE
We are pleased to present the 2025 Design & Planning Guide, with many updates, including aquatherm blue® MF RP (PP-RCT). Read More
PLANNING GUIDE AND PARTS GUIDE
We’re excited to announce the release of the new Aquatherm Design & Planning Guide and its companion piece, the Aquatherm Parts Guide. Formally referred to as our Product Catalog, these Guides deliver updated information on planning and designing piping systems using North America’s preeminent polypropylene piping system. Read More
MAJOR PHARMACEUTICAL MANUFACTURER SOLVES PIPING ISSUES WITH AQUATHERM GREEN PIPE
April 19th, 2013
In January 2013, a major pharmaceutical manufacturer located in the Northeast faced a domestic water piping retrofit at one of its biopharmaceutical research centers. DECCO, a Brookline, NH-based mechanical contractor that has extensive experience in the mechanical aspects of “bio-pharm” applications, was called upon as a project engineer to come up with a solution. In Read More
INSULATION ALTERNATIVES
December 27th, 2012
TECHNICAL BULLETIN: 201212B-AQTTB Date issued: 27 Dec. 2012 Recently Aquatherm announced that Aquatherm Advanced (Reflectix) was being discontinued. Aquatherm is getting out of the insulation business. In the meantime, it is recognized that an alternative to Aquathem Advanced needs to be provided. While Aquatherm does not promote one brand of insulation over another, the accompanying Read More
INTERNAL ALIGNMENT
November 28th, 2012
Due to gravity and the physics of extrusion, larger pipes tend to be slightly thicker on the bottom than they are on the top. However, the top will always be at least as thick as the production SDR, so there is no concern over pressure and temperature ratings. This difference is not enough to cause Read More
Underground Thermal Expansion in Aquatherm Pipe
November 1st, 2012
201211A – AQTTB Date Issued: 6 December 2012 The need for thermal expansion joints in piping systems arises from the tendency of the pipe to expand or contract due to changes in temperature of the pipe material. This expansion can either be directed to a specific location (i.e. expansion joint) by anchoring the pipe away Read More
AQUATHERM AND PIPE INSULATION
October 25th, 2012
Aquatherm pipe has a high thermal resistance value, giving a level of natural insulation to the pipe. With this high level of thermal resistance many have supposed that Aquatherm pipe can be installed in many instances without thermal insulation. While this may indeed be true in some instances, most of the time and according to Read More
PP-R PIPE SYSTEM ENDURES “CRAZY DRUMMER” AND CAUSTIC CHEMICALS AT TANK FARM
October 19th, 2012
Situated in Muskegon, MI on about 20 acres dissected by active rail lines, Webb Chemical Service Corporation is a full-service chemical repackaging and distribution facility. The 50-year-old business provides commodity chemicals to a huge variety of industries including industrial, pharmaceutical, household, agricultural, aerospace, and many others throughout the U.S. Webb Chemical grew from its commitment Read More
THE ULTIMATE MISSION CRITICAL APPLICATION RELIES ON AQUATHERM PP-R PIPE FOR COOLING
October 16th, 2012
Lawrence Livermore National Laboratory (LLNL) is an enduring symbol of America’s scientific and military proficiency. Located in Livermore, CA, LLNL’s stated mission is strengthening U.S. security through development and application of world-class science and technology to: Enhance the nation’s defense; Reduce the global threat from terrorism and weapons of mass destruction; And respond with vision, Read More
Aquatherm and Hanger Spacing
September 14th, 2012
201209A – AQTTB Date Issued: 13 September 2012 New Construction Pipes typically are found in groups of various sizes running side by side. This can ease installation by allowing multiple pipes to rest on a single trapeze pipe support. But every differing pipe size has different support spacing, complicating this approach. Aquatherm has developed a Read More
Water Hammer
August 31st, 2012
201208B – AQTTB Date Issued: 15 August 2012 Many state and local codes require the installation of water hammer arrestors at locations of quick closing valves. This is done to protect metallic pipe from the high-pressure shocks that can occur when these valves are actuated. The pressure surge, and its effect on the pipe, is Read More
Piping Condensation and Aquatherm
August 31st, 2012
201208A – AQTTB Date Issued: 15 August 2012 Condensation on any surface depends on the temperature of the surface, the ambient air temperature and the ambient relative humidity level. The relative humidity level is the amount of moisture or water vapor that is contained in the air at a certain temperature compared to the maximum Read More
